Autopage C3-RS-915 LCD Installation Manual

Browse online or download Installation Manual for Car alarm Autopage C3-RS-915 LCD. Autopage C3-RS-915 LCD Installation manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 37
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
C3 RS915 REV. A
1
C3-RS-915
PROFESSIONAL 2-WAY 915 MHz. LCD REMOTE
CAR STARTER & 6 CHANNEL ALARM SYSTEM
With
Built-in Voltage & Temperature Sensor
And Two Way Serial Port Data Link
INSTALLATION MANUAL
Compatible
THIS PRODUCT IS DESIG
NED FOR PROFESSIONAL INSTALLATION ONLY
Page view 0
1 2 3 4 5 6 ... 36 37

Summary of Contents

Page 1 - C3-RS-915

C3 RS915 REV. A 1 C3-RS-915 PROFESSIONAL 2-WAY 915 MHz. LCD REMOTE CAR STARTER & 6 CHANNEL ALARM SYSTEM With Built-in Voltage & Temperature

Page 2 - TABLE OF CONTENTS:

C3 RS915 REV. A 10 H6: 22 PIN WIRE CONNECTORS: H6/1 BROWN/BLACK WIRE: 200 mA (-) Ground Output When Running. This wire provides a negative output du

Page 3

C3 RS915 REV. A 11This output is for a Key Sense wire by -pass that some Chrysler and Toyota vehicles need to activate remote start. This wire comes o

Page 4

C3 RS915 REV. A 12When the BLACK/WHITE wire is grounded, the remote start unit is operable. When this wire is open from ground, the remote start is di

Page 5

C3 RS915 REV. A 13instance, this timer output may be used to turn on the headlight with the remote control. Also on certain BMW, Mercedes Benz, Jaguar

Page 6

C3 RS915 REV. A 14 H6/14 Yellow wire – (-) 200mA Ignition 3 Output – This wire provides a 200mA (-) ground output that becomes active 4 seconds befor

Page 7

C3 RS915 REV. A 15To + 12 VIgnitionSwitchYELLOW wireMatching ResistorVATS control Module87a86308785VAT wire (#1)VAT wire(#2) H6/15 Green wire – Neg

Page 8

C3 RS915 REV. A 16The WHITE/BLACK wire provides an instant shutdown for the remote start, whenever it is grounded. Connect the wire to the hood pin sw

Page 9

C3 RS915 REV. A 17Blue WireGreen Wire( - ) Lock Pulse( + ) Unlock Pulse( - ) Unlock Pulse(+) Lock PulseRed(not used) NEGATIVE TRIGGER DOOR LOCK SYSTEM

Page 10 - H6: 22 PIN WIRE CONNECTORS:

C3 RS915 REV. A 182 STEP DOOR UNLOCK WIRE CONNECTION FOR GROUND SWITCHED DOOR LOCKS Cut Existing Unlock X Lock Unlock OEM Door Master Lock Switch To A

Page 11 - C3 RS915 REV. A

C3 RS915 REV. A 19 Press Transmitter Button One Chirp / LED one pulse Factory Default Setting Two Chirps / LED two pulses Three Chirps / LED three pul

Page 12

C3 RS915 REV. A 2 TABLE OF CONTENTS: INSTALLATION DIAGRAMS 4 H1: 6 PIN HEAVY GAUGE WIRING CONNECTION 6 H1/1 Violet Wire – Starter Output 6 H1/2

Page 13

C3 RS915 REV. A 201 Turn the Ignition switch ‘ON/OFF’ 3 TIMES and stay in OFF position. 2 Push the Valet switch 5 times (holding in on the 5th pus

Page 14

C3 RS915 REV. A 21(The system Can not be Arm with the engine running) The shock sensor will be by-passed upon engine running. (The engine will run b

Page 15 - To White/ Violet

C3 RS915 REV. A 222 H6/6 Brown / White Wire = (-) 200mA Horn Output H6/6 Brown / White Wire = Factory Security Rearm Signal Output 3 Fahrenheit

Page 16

C3 RS915 REV. A 233. When the desired interval has passed, release the valet switch. 1 long chirp for confirmation. (Set to any interval between 1 s

Page 17 - 5-WIRE ALTERNATING DOOR LOCK

C3 RS915 REV. A 242. Push the Valet switch 7 times (holding in on the 7th push) it until three chirps with one long chirp is heard then release the va

Page 18 - GROUND SWITCHED DOOR LOCKS

C3 RS915 REV. A 255 Door lock before start Door lock after shut-down Door lock before start and Door lock after shut-down Without this feature 6

Page 19

C3 RS915 REV. A 265 Start or Stop the system for TESTING & ADJUSTMENT 6 + “TEST” Mode for Zone 2 / instant trigger & Zone 3 / Door tri

Page 20

C3 RS915 REV. A 276. Press and hold the valet switch for 2 seconds until a long chirp and the LED light constant for two seconds. The RPM signal is le

Page 21

C3 RS915 REV. A 28b. Press button on the transmitter to set proper “Start Timer”. The chirp & LED pause will confirm entry. (Decrease “Start T

Page 22

C3 RS915 REV. A 29Press and release the transmitter and buttons at the same time once. [1] LED flash, [1] siren/horn chirp to indicate your are

Page 23

C3 RS915 REV. A 3Test the Hood Pin shutdown circuit 31 Neutral Start Safety Test 31 Mechanical Neutral Safety Switch Considerations 31 Park/Neutral

Page 24

C3 RS915 REV. A 30TROUBLE SHOOTING There are 5 reasons why the remote start button will not respond from the transmitter. 1. The Black/White Neutr

Page 25

C3 RS915 REV. A 31Failure to test the unit in the following manner may result in personal injury, property damage, or both. 1. Test the BRAKE shutdown

Page 26 - IMPORTANT NOTE:

C3 RS915 REV. A 32installing the Remote Start Unit in. 2. Connect the BLACK/WHITE Neutral Safety Switch wire (H6/8) to this reference wire. NOTE: If

Page 27

C3 RS915 REV. A 33A. Locate the control wire that connects the driver’s door pin switch to the key in sensor switch. B. Cut this wire and connect th

Page 28

C3 RS915 REV. A 34 Available At an Authorized Autopage Dealer The RS-900 is CI3 Compatible It is recommended to have a minimal digital service plan

Page 29

C3 RS915 REV. A 35 BLANK PAGE

Page 30

C3 RS915 REV. A 36 960 Knox Street Unit B Torrance, California 90502 Main Office: 310-323-1800 Technical Support: 800-945-252

Page 31

C3 RS915 REV. A 37www.autopageusa.com 2-Way Communication to the Power of 3

Page 32 - METHOD 1

C3 RS915 REV. A 4 INSTALLATION DIAGRAM

Page 33 - Ignition Key In Sensor

C3 RS915 REV. A 520A20ARed: Remote Start Power 1Red: Remote Start Power 2Violet: Starter (+) OutputPink: Ignition 2 (+) OutputYellow: Ignition 1 (+) O

Page 34

C3 RS915 REV. A 6 WIRING Keep wiring away from moving engine parts, exhaust pipes and high-tension cable. Be sure to tape wires that pass through

Page 35

C3 RS915 REV. A 7 Red Wire (2) — +12V Power Input Remove the two 20A fuses prior to connecting these wires and do not replace them until the satellite

Page 36

C3 RS915 REV. A 8serial data modules and is not included with the RS-900. This two-way data port has been designed for use with all C I 3 compatible

Page 37

C3 RS915 REV. A 9H7. 4-PIN BLACK CONNECTOR. – TWO-WAY TRANSCEIVER/ANTENNA MODULE The Two-way transceiver/antenna mounting location should be the upper

Comments to this Manuals

No comments